1990 FORD F350 — Problems, Recalls & Safety Data

Check any vehicle history by VIN - Free vehicle history report

N/A

Safety Rating

63

Owner Complaints

4 Fires 1 Death

7

Recalls

ACTIVE RECALL

3

Service Bulletins

0

Investigations

Overview of the 1990 FORD F350

The 1990 FORD F350 has received a total of 63 safety complaints filed with the National Highway Traffic Safety Administration (NHTSA). There have been 7 recall campaigns affecting this vehicle, covering issues with FUEL SYSTEM, GASOLINE, ELECTRICAL SYSTEM:IGNITION, FUEL SYSTEM, GASOLINE:DELIVERY:HOSES, LINES/PIPING, AND FITTINGS. 3 technical service bulletins have been issued by Ford Motor Company for this model year. The most commonly reported problems involve the Service Brakes Hydraulicfoundation Components (9 complaints), Service Brakes Hydraulicantilocktraction Controlelectronic Limited Slip (5 complaints), and Engine And Engine Coolingenginegasoline (4 complaints).

Recalls for the 1990 FORD F350

NHTSA has recorded 7 recalls for the 1990 FORD F350, potentially affecting up to 11,256,091 vehicles.

Recall 01I008000 — FUEL SYSTEM, GASOLINE

| 1,556,221 vehicles affected

Defect: THIS IS NOT A SAFETY RECALL IN ACCORDANCE WITH THE SAFETY ACT. HOWEVER, IT IS DEEMED A SAFETY IMPROVEMENT CAMPAIGN BY THE AGENCY. VEHICLE DESCRIPTION: 1990-1993 FORD F-SERIES VEHICLES EQUIPPED WITH DUAL FUEL TANKS AND 4.9, 5.0,5.8, OR 7.5 LITER GASOLINE FUELED ENGINES. SOME VEHICLES CAN EXPERIENCE A CROSS TANK FUEL FLOW CONDITION DUE TO A DAMAGED CHECK VALVE IN...

Consequence: SHOULD THIS OCCUR, THE CAPACITY OF THE RECEIVING TANK MAY BE EXCEEDED AND FUEL MAY OVERFLOW FROM THE FILLER CAP.

Remedy: FORD IS EXTENDING THE WARRANTY FOR POTENTIAL FUEL CROSS-FLOW TO 12 YEARS OF SERVICE OR 150,000 MILES FROM THE VEHICLE'S WARRANTY START DATE, WHICHEVER OCCURS FIRST. THIS COVER WILL AUTOMATICALLY TRANSFER TO SUBSEQUENT OWNERS AT NO CHARGE. IF A VEHICLE...

View full details →

Recall 96V071000 — ELECTRICAL SYSTEM:IGNITION

| 7,900,000 vehicles affected

Defect: THE IGNITION SWITCH COULD EXPERIENCE AN INTERNAL SHORT CIRCUIT.

Consequence: THIS CONDITION COULD CAUSE OVERHEATING, SMOKE, AND POSSIBLY FIRE IN THE STEERING COLUMN AREA OF THE VEHICLE.

Remedy: DEALERS WILL REPLACE THE IGNITION SWITCH.

View full details →

Recall 94V040000 — FUEL SYSTEM, GASOLINE:DELIVERY:HOSES, LINES/PIPING, AND FITTINGS

| 89,770 vehicles affected

Defect: THE STEEL FUEL RETURN TUBES THAT CONNECT THE FRAME FUEL RETURN LINES WITH THE ENGINE FUEL RAIL CAN CONTACT THE PINCH WELD FLANGE CONNECTING THE DASH PANEL TO THE FLOOR PAN. CONTINUED CONTACT LEADS TO ABRASION OF THE STEEL FUEL RETURN TUBE AND EVENTUALLY RESULTS IN A FUEL LEAK.

Consequence: ABRASION OF THE STEEL TUBE WALL THAT EVENTUALLY CAUSES A FUEL LEAK MAY RESULT IN A FIRE, IF A SOURCE OF IGNITION IS PRESENT.

Remedy: FORD DEALERS WILL REPLACE THE FUEL RETURN TUBES WITH FLEXIBLE STAINLESS STEEL BRAIDED/TEFLON TUBES. DEALERS WILL ALSO INSPECT THE FUEL SUPPLY TUBES.

View full details →

Recall 93V125000 — FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY

| 1,131,000 vehicles affected

Defect: A MALFUNCTIONING CHECK VALVE WITHIN THE FUEL PUMP ASSEMBLY CAUSES A PORTION OF THE UNUSED FUEL FROM ONE TANK TO BE RETURNED TO THE SECOND TANK. WHEN THIS OCCURS, THE CAPACITY OF THE SECOND TANK CAN BE EXCEEDED, CAUSING FUEL SPILLAGE.

Consequence: SPILLED FUEL CAN RESULT IN A FIRE WHEN EXPOSED TO ASOURCE OF IGNITION.

Remedy: REPLACEMENT OF THE FUEL PRESSURE REGULATOR AND INSTALLATION OF REDUNDANT CHECK VALVES.

View full details →

Recall 92V026000 — SERVICE BRAKES, HYDRAULIC:FOUNDATION COMPONENTS:DRUM:SHOES/LININGS

| 467,000 vehicles affected

Defect: A REVISED BRAKE LINING NOISE INSULATOR RESULTED IN A DECREASE IN THE THERMAL INSULATION BETWEEN THE BRAKE LINING AND THE FRONT BRAKE CALIPER PISTON. THIS CAUSED GREATER HEAT TRANSFER TO THE CALIPER PISTONS WITH THE POTENTIAL TO OVERHEAT THE BRAKE FLUID AND DIMINISH BRAKE EFFECTIVENESS DURING SEVERE BRAKING CONDITIONS.

Consequence: INCREASED STOPPING DISTANCES AND INABLILITY TO HOLDVEHICLES ON A STEEP GRADE RESULTS IN INCREASED RISK OF ACCIDENT IN THE EVENT OFA SUDDEN STOP OR WHEN CONSTANT BRAKING IS NEEDED TO MANEUVER THROUGH AREAS WITHSTEEP GRADES.

Remedy: ADD SNAP-IN INSULATORS THAT ATTACH TO EACH OF THE FRONT BRAKE CALIPER PISTONS. IN ADDITION, VEHICLES WITH 7.5 L ENGINES WILL HAVE INSULATION ADDED TO THE ENGINE COMPARTMENT BRAKE LINES.

View full details →

Recall 90V101000 — POWER TRAIN:AUTOMATIC TRANSMISSION:GEAR POSITION INDICATION (PRNDL)

| 111,000 vehicles affected

Defect: UNDER CERTAIN CONDITIONS, THE SNAP RING THAT LOCATES THE PARK GEAR ON THE OUTPUT SHAFT OF THE TRANSMISSION MAY FRACTURE.

Consequence: WHEN THE GEAR IS PLACED IN PARK, THE PARK GEAR WOULD NOTENGAGE, ALLOWING THE TRUCK TO ROLL FREELY IF THE PARKING BRAKE IS NOT PROPERLYSET. THIS COULD RESULT IN AN ACCIDENT.

Remedy: INSTALL IMPROVED SNAP RING AND REVISED TRANSMISSION EXTENSION HOUSING.

View full details →

Recall 89V141000 — FUEL SYSTEM, GASOLINE:STORAGE:AUXILLARY TANK:SELECTOR DEVICES

| 1,100 vehicles affected

Defect: INCORRECTLY INSTALLED FUEL LINE CONNECTORS HAVE FUEL SUPPLY AND RETURN LINES CROSSED.

Consequence: FUEL COULD BE TRANSFERRED FROM ONE TANK TO THE OTHER,POSSIBLY RESULTING IN FUEL OVERFLOW AND SPILLAGE, IN PRESENCE OF AN IGNITIONSOURCE, A FIRE COULD OCCUR.

Remedy: REPLACE FUEL LINE ASSEMBLY.

View full details →

Owner Complaints for the 1990 FORD F350

63 complaints have been filed with NHTSA for the 1990 FORD F350. Below is a breakdown by vehicle component.

Service Brakes Hydraulicfoundation Components
Complaints: 9 5 Injuries 1 Death
Service Brakes Hydraulicantilocktraction Controlelectronic Limited Slip
Complaints: 5
Engine And Engine Coolingenginegasoline
Complaints: 4
Fuel System Gasolinestorageauxillary Tankselector Devices
Complaints: 4
Engine And Engine Coolingengine
Complaints: 2
Engine And Engine Coolingexhaust System
Complaints: 2
Fuel System Gasolinestoragetank Assembly
Complaints: 2
Power Trainautomatic Transmission
Complaints: 2
Suspensionfront
Complaints: 2
Electrical Systemignition
Complaints: 1 1 Fire 1 Injury
Electrical Systemignitionswitch
Complaints: 1
Electrical Systemwiringfront Underhood
Complaints: 1 1 Fire
Electrical Systemwiringfuses And Circuit Breakers
Complaints: 1
Engine And Engine Coolingenginediesel
Complaints: 1
Engine And Engine Coolingexhaust Systememission Controlcatalytic Convertor
Complaints: 1
Engine And Engine Coolingexhaust Systemmanifoldheadermufflertail Pipe
Complaints: 1 1 Fire
Fuel System Gasolinedelivery
Complaints: 1
Fuel System Gasolinedeliveryfuel Pump
Complaints: 1
Fuel System Gasolinefuel Injection Systeminjectors
Complaints: 1
Fuel System Gasolinestorageauxillary Tank
Complaints: 1
Power Trainautomatic Transmissiontorque Converter
Complaints: 1
Power Trainaxle Assemblyaxle Shaftseal
Complaints: 1
Power Trainclutch Assembly
Complaints: 1
Power Trainclutch Assemblypedalhand Levermotorcycle
Complaints: 1 1 Fire
Seat Belts
Complaints: 1
Service Brakes Hydraulicbrake Fluid Low Warning Lamp
Complaints: 1
Service Brakes Hydraulicfoundation Componentsdisc
Complaints: 1
Service Brakes Hydraulicfoundation Componentsdisccaliper
Complaints: 1
Service Brakes Hydraulicfoundation Componentsdiscpads
Complaints: 1
Service Brakes Hydraulicfoundation Componentsdiscrotor
Complaints: 1
Service Brakes Hydraulicfoundation Componentsmaster Cylinder
Complaints: 1
Service Brakes Hydraulicpower Assisthydraulic
Complaints: 1
Service Brakes Hydraulicpower Assistvacuum
Complaints: 1
Steeringlinkagestie Rod Assembly
Complaints: 1
Structurebodydoor
Complaints: 1
Suspensionfrontwheel Bearing
Complaints: 1
Tires
Complaints: 1
Tirestreadbelt
Complaints: 1
Unknown Or Other
Complaints: 1
Visibilitywindshield Wiperwashermotor
Complaints: 1

Most Recent Complaints

DT: THE CROSS OVER OF THE FUEL IMPROPERLY OVERFILLS THE SECOND TANK, SPILLING FUEL OUT OF VEHICLE. THERE WERE 2 SAFETY RECALLS OF THIS ITEM. BUT FORD WAS SAYING THAT ONE RECALL WAS TAKEN CARE OF BY A PREVIOUS OWNER. THE SECOND RECALL EXPIRED, AND FORD WILL NOT FIX THIS PROBLEM. FORD HAS BEEN CONTACTED BY THE CUSTOMER AND THE REPAIR FACILITY. FORD WAS STILL NOT WILLING TO HELP. THIS HAS BEEN A PROBLEM FOR A COUPLE OF MONTHS. THE CUSTOMER WAS HAVING IT REPAIRED AT HIS OWN EXPENSE. IF THERE WAS A SAFETY ISSUE ON THIS PROBLEM IT SHOULD BE TAKEN CARE OFF BY DEALER NO MATTER HOW MANY TIMES IT COMES UP.*AK *JB
#10089939 | FUEL SYSTEM, GASOLINE:STORAGE:AUXILLARY TANK | | 180,000 miles
VEHICLE WAS TAKEN TO DEALER FOR RECALL REPAIRS ABOUT 5 YEARS AGO. VEHICLE HAD DUEL GAS TANKS. THE RECALL WAS ISSUED BECAUSE ONE TANK WOULD PUMP GAS INTO THE OTHER TANK, AND WHEN IT WAS FULL IT WOULD SPILL OVER, CREATING A FIRE HAZARD. AFTER RECALL REPAIRS WERE DONE THE PROBLEM RECURRED. CONSUMER FELT THAT THE PROPER WORK FOR THE RECALL WAS INSUFFICIENTLY DONE BECAUSE OF WHAT WAS HAPPENING CURRENTLY. *AK
#10024386 | TIRES:TREAD/BELT | | 1,500 miles
WHILE TRAVELING, THE CONSUMER HEARD A LOUD POPPING NOISE. THE CONSUMER PULLED OVER AND SAW THE RIGHT FRONT TIRE TREAD SEPARATED FROM THE WHEEL. FIRESTONE STEELTEX, LT 265/75R16. *AK *SCC *JB
#757905 | FUEL SYSTEM, GASOLINE:DELIVERY | | N/A miles
I AM SPEAKING ON BEHALF OF THE OWNER, I AM TED SCHORE OF OCALA,FL PINEYWOODS AUTOMOTIVE 352-629-6727 THE CUSTOMER HAD THE TRUCK TOWED IN BECAUSE OF A NO START (BATTERY WAS BAD) AND AFTER THE REPAIR AND RUNNING NOTICED A FUEL SMELL AND LARGE FUEL LEAK FROM THE BELL HOUSING AREA. THE LEAK WAS FROM THE FUEL RETURN LINE FROM THE PRESSURE REGULATOR TO THE CONNECTION TO THE LINE FROM THE TANK, APPROX 12 INCHES LONG AND METAL. THE PINCH WELD ABOVE THE BELL HOUSING RUBBED THE LINE THROUGH. I CHECK FOR SERVICE BULLETINS AND RECALLS AND FOUND A RECALL NUMBER 94S80, I CALLED THE LOCAL FORD DEALER TO ARRANGE TOWING AND FOR THE RECALL TO BE PERFORMED AND WAS TOLD THE RECALL HAD ALREADY BEEN DONE BY BAY HARBOR FORD IN ENGLEWOOD FLORIDA. I CALLED THE 1-800 NUMBER GIVEN TO ME BY THE LOCAL DEALER (DEARBORN?) AND WAS TOLD THE IT HAD INDEED BEEN DONE BUT THEY WERE NOT GOING TO DO ANYTHING ABOUT IT NOW, I INFORMED THEM THAT ALTHOUGH THEY SHOW IT BEING DONE THAT IT WAS NOT THEY PRETTY MUCH SAID IT WAS NOT FORDS PROBLEM AND THE CUSTOMER WOULD HAVE TO PAY TO HAVE IT REPAIRED. WELL MY PROBLEM IS THIS. THE BAY HARBOR FORD HAS BEEN PAID TO PERFORM THE RECALL BUT IT HAS NOT BEEN DONE. THE OLD LINE WAS METAL WHERE THE NEW RECALL WAS FOR A PLASTIC LINE, THE KIT ALSO HAD A VINYL TRIM PIECE TO COVER THE PINCH WELD THAT RUBBED THE LINE IN THE FIRST PLACE. THE KIT NUMBER FROM FORD WAS F4TZ-9J332-A I WAS TOLD IT WAS ON NATIONAL BACK ORDER BUT THE PARTS MAN WAS ABLE TO GET IT THROUGH ANOTHER FORD DEALER. I JUST WANTED TO INFORM YOU OF THIS BECAUSE IT WAS A REAL FIRE DANGER AND UNSAFE TO DRIVE. FORD"S ATTITUDE WAS JUST PLAIN WRONG. I WOULD THINK THAT THE DEARBORN OFFICE WOULD HAVE PAID TO HAVE THE TRUCK TOWED TO THE NEAREST DEALER, INSPECTED, MADE NOTE OF THE RECALL NOT BEING DONE, PERFORMED THE RECALL AND GO AFTER BAY HARBOR FORD, BUT IN SO MANY WORDS I WAS TOLD TOUGH. I THINK I SAVED THEM FROM A BIG LAWSUIT AS THE CUSTOMER HAULS HORSES. BIG DOLLAR HORSES.
#757633 | FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY | | N/A miles
THERE HAS BEEN MULTIPLE RECALL NOTICES FOR THE FORD F-SERIES DUAL FUEL TANK DESIGN FLAW. WHEN BOTH TANKS ON MY TRUCK ARE FILLED TO CAPACITY, ONE TANK WILL EMPTY ITS CONTENTS INTO THE OTHER FULL FUEL TANK AND WILL SPRAY OUT FUEL ON TO THE ROAD AND OTHER VEHICLES POSING A GREAT FIRE HAZARD. EACH TIME I HAVE TAKEN MY TRUCK IN TO HAVE THE RECALL PERFORMED ON MY TRUCK BY THE LOCAL DEALER (MCCULLOM FORD IN SPOKANE WA) THEY HAVE RETURNED MY TRUCK WITHOUT FIXING THE PROBLEM. THEY HAVE INDICATED THAT THEY HAVE PERFORMED FORDS RECOMMENDED FIX AND THAT IT HAS NOT SOLVED THE PROBLEM. THIS IS A FORD MOTOR CO. DESIGN FLAW. I WOULD LIKE MORE INFORMATION ON HOW I CAN HAVE THIS UNSAFE CONDITION ADDRESSED. THANK YOU.*AK

View all Service Brakes Hydraulicfoundation Components complaints →

Safety Rating for the 1990 FORD F350

NHTSA has not yet tested the 1990 FORD F350 in its New Car Assessment Program.

Technical Service Bulletins for the 1990 FORD F350

Ford Motor Company has issued 3 technical service bulletins (TSBs) for the 1990 FORD F350. TSBs are notices sent by manufacturers to their dealers describing a known issue and the recommended repair procedure.

98115 — STRUCTURE:BODY:BUMPERS

INFORMATION REGARDING RANDOM HAIRLINE CRACKS, "STAR CRACKING" IN REAR SHEET MOLDING COMPOSITE (SMC) FENDERS - DUAL REAR VEHICLES OPERATING IN SEVERE DUTY CONDITIONS. *TT

96728 — POWER TRAIN:CLUTCH ASSEMBLY

SERVICE TIP INFORMATION REGARDING THE REVERSE CLUTCH PISTON AND PISTON SEAL USAGE. *TT

95711 — ENGINE AND ENGINE COOLING:EXHAUST SYSTEM

SOME VEHICLES MAY EXHIBIT A LACK OF POWER OR A NO START CONDITION DUE TO AN EXHAUST RESTRICTION. *TW

NHTSA Investigations for the 1990 FORD F350

There are no NHTSA defect investigations on record for this vehicle.