1993 FORD E-150 — Problems, Recalls & Safety Data

Check any vehicle history by VIN - Free vehicle history report

N/A

Safety Rating

95

Owner Complaints

10 Crashes 6 Fires

4

Recalls

ACTIVE RECALL

0

Service Bulletins

0

Investigations

Overview of the 1993 FORD E-150

The 1993 FORD E-150 has received a total of 95 safety complaints filed with the National Highway Traffic Safety Administration (NHTSA). There have been 4 recall campaigns affecting this vehicle, covering issues with VEHICLE SPEED CONTROL, VEHICLE SPEED CONTROL:CRUISE CONTROL. The most commonly reported problems involve the Vehicle Speed Control (6 complaints), Engine And Engine Coolingenginegasoline (4 complaints), and Fuel System Gasolinedeliveryfuel Pump (4 complaints).

Recalls for the 1993 FORD E-150

NHTSA has recorded 4 recalls for the 1993 FORD E-150, potentially affecting up to 8,331,088 vehicles.

Recall 09V399000 — VEHICLE SPEED CONTROL

| 4,500,000 vehicles affected

Defect: FORD IS RECALLING MODEL YEARS 1995-2003 WINDSTAR, 2000-2003 EXCURSION DIESEL, 1993-1997 AND 1999-2003 F-250 SD THROUGH F-550 SD DIESEL, 1992-2003 E-150 THROUGH E-550, 1995-2002 EXPLORER, 1997 AND 2002 MERCURY MOUNTAINEER, 1995-1997 AND 2001-2003 RANGER, AND 1994 F53 VEHICLES EQUIPPED WITH THE TEXAS INSTRUMENTS SPEED CONTROL DEACTIVATION SWITCH (SCDS). THE SCDS MAY LEAK INTERNALLY AND THEN OVERHEAT, SMOKE, OR BURN.

Consequence: A VEHICLE FIRE COULD OCCUR WITH OR WITHOUT THE ENGINE RUNNING.

Remedy: FORD WILL NOTIFY OWNERS THAT DEALERS WILL INSTALL A FUSED WIRING HARNESS IN LINE WITH THE SCDS. ON 1999-2003 WINDSTAR VEHICLES WITH A LEAKING SCDS, DEALERS WILL ALSO INSPECT THE ABS CONTROL MODULE CONNECTOR AND REPAIR AS NECESSARY. REPAIRS WILL...

View full details →

Recall 08V051000 — VEHICLE SPEED CONTROL:CRUISE CONTROL

| 225,000 vehicles affected

Defect: FORD IS RECALLING 225,000 MY 1992-2003 ECONOLINE, MY 1993-1995 TAURUS SHO, MY 1992-1998 CROWN VICTORIA, MY 1993 BRONCO, F-SERIES, MY 1995-1997 F-SERIES SUPER DUTY STRIPPED CHASSIS, MY 1992-1998 MERCURY GRAND MARQUIS, AND MY 1992-1995 LINCOLN TOWN CAR VEHICLES. THE AFFECTED VEHICLES WERE PREVIOUSLY REPAIRED USING A WIRING HARNESS THAT IS NOT COMPATIBLE WITH THE VEHICLE CIRCUIT POLARITY.

Consequence: AS A RESULT, THE FUSE IS LOCATED IN THE OUTPUT CIRCUIT RATHER THAN IN THE INTENDED INPUT POWER FEED CIRCUIT, AND MAY NOT OFFER THE INTENDED PROTECTION IN THE EVENT OF AN ELECTRICAL SHORT TO GROUND.

Remedy: DEALERS WILL INSTALL A NEW WIRING HARNESS, OR REPLACE THE MATING ELECTRICAL COMPONENT. THE RECALL BEGAN ON FEBRUARY 18, 2008. OWNERS MAY CONTACT FORD AT 1-800-392-3673.

View full details →

Recall 07V336000 — VEHICLE SPEED CONTROL

| 3,600,000 vehicles affected

Defect: ON CERTAIN PICKUP TRUCKS, PASSENGER VEHICLES, SPORT UTILITY VEHICLES, AND MOTOR HOMES CHASSIS, THE SPEED CONTROL DEACTIVATION SWITCH MAY, UNDER CERTAIN CONDITIONS, LEAK INTERNALLY AND THEN OVERHEAT, SMOKE, OR BURN.

Consequence: THIS COULD RESULT IN AN UNDERHOOD FIRE.

Remedy: DEALERS WILL INSTALL A FUSED WIRING HARNESS. OWNERS OF THE PASSENGER CARS INCLUDED IN THIS CAMPAIGN WILL BE INSTRUCTED TO RETURN THEIR VEHICLES TO THEIR DEALERS TO HAVE THE SPEED CONTROL DEACTIVATION SWITCH DISCONNECTED AS AN INTERIM REPAIR. AS SOON...

View full details →

Recall 94V128000 — INTERIOR LIGHTING

| 6,088 vehicles affected

Defect: THE TRANSFORMER USED TO POWER THE NEON CENTER LIGHTBEAM CAN OVERHEAT AND CATCH ON FIRE.

Consequence: THE OVERHEATING AND FIRES CAUSED BY THE NEON TRANSFORMER CAN RESULT IN DAMAGE TO THE LIGHTBEAM ASSEMBLY, THE ROOF OF THE VEHICLE, AND COULD RESULT IN A VEHICLE FIRE.

Remedy: MARK III DEALERS WILL MODIFY THE ASSEMBLIES TO ELIMINATE THE NEON LIGHTING FIXTURE IN THE VEHICLE AND REPLACE IT WITH INCANDESCENT LIGHTS OPERATING DIRECTLY FROM THE VEHICLE 12-VOLT BATTERY.

View full details →

Owner Complaints for the 1993 FORD E-150

95 complaints have been filed with NHTSA for the 1993 FORD E-150. Below is a breakdown by vehicle component.

Vehicle Speed Control
Complaints: 6 4 Crashes 1 Injury
Engine And Engine Coolingenginegasoline
Complaints: 4 1 Fire
Fuel System Gasolinedeliveryfuel Pump
Complaints: 4
Fuel System Gasolinestoragetank Assembly
Complaints: 4
Service Brakes Hydraulicantilocktraction Controlelectronic Limited Slip
Complaints: 4
Steering
Complaints: 4
Tires
Complaints: 4
Air Bagsfrontal
Complaints: 3 3 Crashes 2 Injuries
Electrical Systemignition
Complaints: 3
Power Trainautomatic Transmission
Complaints: 3 1 Crash
Steeringgear Box Other Than Rack And Pinion
Complaints: 3
Tirestreadbelt
Complaints: 3
Engine And Engine Coolingcooling Systemhoseslinespipingfittings
Complaints: 2
Equipmentapplianceair Conditioner
Complaints: 2 1 Fire
Service Brakes Hydraulicfoundation Components
Complaints: 2
Service Brakes Hydraulicfoundation Componentshoses Linespiping And Fittings
Complaints: 2
Structure
Complaints: 2
Structureframe And Membersunderbody Shields
Complaints: 2
Unknown Or Other
Complaints: 2
Wheelslugsnutsboltsstuds
Complaints: 2
Wheelsrim
Complaints: 2
Electrical System
Complaints: 1 1 Fire
Electrical Systemignitionswitch
Complaints: 1
Electrical Systemwiring
Complaints: 1
Electrical Systemwiringfuses And Circuit Breakers
Complaints: 1 1 Fire
Engine And Engine Coolingcooling Systemradiator Assembly
Complaints: 1 1 Crash
Engine And Engine Coolingexhaust Systememission Control
Complaints: 1
Equipment Adaptivemobility
Complaints: 1
Exterior Lighting
Complaints: 1
Fuel System Gasolinedelivery
Complaints: 1
Fuel System Gasolinefuel Injection System
Complaints: 1
Fuel System Gasolinestoragetank Assemblyfiller Pipe And Cap
Complaints: 1
Fuelpropulsion System
Complaints: 1
Interior Lighting
Complaints: 1
Power Train
Complaints: 1
Power Trainaxle Assemblyaxle Shaft
Complaints: 1 1 Crash
Seat Beltsfrontanchorage
Complaints: 1
Seat Beltsrearother
Complaints: 1
Service Brakes Hydraulicfluid
Complaints: 1
Service Brakes Hydraulicfoundation Componentsdiscrotor
Complaints: 1
Steering Steering Wheelhandle Bar
Complaints: 1
Steeringhydraulic Power Assistpump
Complaints: 1
Steeringlinkagesknucklespindlearm
Complaints: 1
Suspension
Complaints: 1
Suspensionfront
Complaints: 1
Suspensionfrontcontrol Arm
Complaints: 1
Suspensionfrontcontrol Armlower Ball Joint
Complaints: 1
Suspensionfrontcontrol Armupper Ball Joint
Complaints: 1
Suspensionfrontwheel Bearing
Complaints: 1
Suspensionsubframemounting Bracket
Complaints: 1
Visibilitydefrosterdefoggerhvac Systemfanmotor
Complaints: 1 1 Fire
Visibilityrearview Mirrorsdevices
Complaints: 1 1 Fire
Visibilitywindshield Wiperwashermotor
Complaints: 1

Most Recent Complaints

#11472754 | POWER TRAIN | | 200,000 miles
The contact owns a 1993 Ford E-150. The contact stated that upon attempting to pull into a parking space and turning the steering wheel, she heard an abnormal sound coming from underneath the front driver's side seat and the steering wheel seized. There was no warning light illuminated. The contact contacted AAA who inspected the vehicle and informed the contact that the gear box had detached from the subframe. The vehicle was towed to an independent mechanic where it was diagnosed that the front driver's side subframe had three holes and one of the holes had expanded significantly and needed to be welded prior to fastening the gear box to the subframe. The independent mechanic informed the contact that they could not weld the subframe. The dealer was notified and informed the contact that the next availability was in approximately two months. The vehicle was not repaired. The manufacturer was notified of the failure but provided no assistance. The failure mileage was approximately 200,000.
#11472754 | SUSPENSION:SUBFRAME/MOUNTING BRACKET | | 200,000 miles
The contact owns a 1993 Ford E-150. The contact stated that upon attempting to pull into a parking space and turning the steering wheel, she heard an abnormal sound coming from underneath the front driver's side seat and the steering wheel seized. There was no warning light illuminated. The contact contacted AAA who inspected the vehicle and informed the contact that the gear box had detached from the subframe. The vehicle was towed to an independent mechanic where it was diagnosed that the front driver's side subframe had three holes and one of the holes had expanded significantly and needed to be welded prior to fastening the gear box to the subframe. The independent mechanic informed the contact that they could not weld the subframe. The dealer was notified and informed the contact that the next availability was in approximately two months. The vehicle was not repaired. The manufacturer was notified of the failure but provided no assistance. The failure mileage was approximately 200,000.
#11222056 | FUEL/PROPULSION SYSTEM | | 186,000 miles
TL* THE CONTACT OWNS A 1993 FORD E-150. WHILE FUELING THE VEHICLE AT A FUEL STATION, THE FUEL WOULD LEAK OUT FROM THE TOP OF THE FUEL TANK. THE VEHICLE WAS TOWED TO THE CONTACT'S RESIDENCE. THE CONTACT WAS CONCERNED FOR HER SAFETY AND CALLED FIRMIN FORD (LOCATED AT 921 E MAIN ST, LAURENS, SC 29360, (864) 682-3111) TO SCHEDULE A DIAGNOSTIC APPOINTMENT. THE CONTACT WAS INFORMED THAT THERE WAS NO RECALL ON THE VEHICLE. THE VEHICLE WAS NOT TAKEN TO A DEALER AND WAS NOT REPAIRED. THE MANUFACTURER WAS NOTIFIED OF THE FAILURE. THE APPROXIMATE FAILURE MILEAGE WAS 186,000.
#10760102 | TIRES | | 36,350 miles
I WAS DRIVING ON I-95 WHEN MY VEHICLE STARTED THUMPING AND VIBRATING ERRATICALLY AND STEERING WAS VERY HARD TO CONTROL. I EXITED IMMEDIATELY TO FIND THAT MY TIRE HAD A HUGE BULGE A LITTLE LARGER THAN A SOFTBALL. A MAN STOPPED AND SAID I SHOULD BE OKAY TO DRIVE THE 2 MILES I HAD LEFT TO GET HOME. WHEN I BACKED OUT TO DRIVE HOME THE BULGE POPPED EXPOSING BROKEN PLY CORDS AND TREAD SEPARATION.
#10502038 | STEERING | | 143,000 miles
DRIVING HOME FROM SHOPPING I BACKED OUT OF A PARKING SPACE AND HEARD A LOUD POPPING SOUND UPON INSPECTION THE 2 MOUNTING BOLTS HOLDING THE GEARBOX TO THE FRAME RAIL HAD SHEARED OFF AND THE 3RD ONE HAD RIPPED THROUGH THE FRAME RAIL COMPLETELY AND DROPPED THE GEARBOX HAD TO HAVE IT TOWED HOME UPON FURTHER INSPECTION THERE ARE STRESS CRACKS AROUND THE MOUNTING HOLES FOR THE GEARBOX BOLTS. *TR

View all Vehicle Speed Control complaints →

Safety Rating for the 1993 FORD E-150

NHTSA has not yet tested the 1993 FORD E-150 in its New Car Assessment Program.

Technical Service Bulletins for the 1993 FORD E-150

No technical service bulletins have been reported for this vehicle.

NHTSA Investigations for the 1993 FORD E-150

There are no NHTSA defect investigations on record for this vehicle.

Other Model Years of the FORD E-150

View all FORD E-150 model years →

Other FORD Models

View all FORD models →

Check any vehicle history by VIN - Free vehicle history report