The 2012 GILLIG LOW FLOOR has received a total of 0 safety complaints filed with the National Highway Traffic Safety Administration (NHTSA). There have been 12 recall campaigns affecting this vehicle, covering issues with ELECTRICAL SYSTEM:WIRING:FUSES AND CIRCUIT BREAKERS, EXTERIOR LIGHTING:TURN SIGNAL. 4 technical service bulletins have been issued by Gillig LLC for this model year.
Recalls for the 2012 GILLIG LOW FLOOR
NHTSA has recorded 12 recalls for the 2012 GILLIG LOW FLOOR, potentially affecting up to 95,099 vehicles.
Recall 20V179000 — ELECTRICAL SYSTEM:WIRING:FUSES AND CIRCUIT BREAKERS
| 8,224 vehicles affected
Defect: Gillig LLC (Gillig) is recalling certain 2012-2020 Low Floor buses. The circuit breaker ratings on the DEF Line Heater circuit and the Aftertreatment-Ignition circuit may be higher than the rating for the wire and connector.
Consequence: With the improper circuit breaker rating, an electrical short in either of these circuits may increase the risk of a fire.
Remedy: Gillig will notify owners, and dealers will replace the circuit breakers, free of charge. The recall began April 24, 2020. Owners may contact Gillig customer service at 1-510-264-5073 or 1-800-735-1500.
View full details →Recall 17V119000 — EXTERIOR LIGHTING:TURN SIGNAL
| 17,056 vehicles affected
Defect: Gillig LLC (Gillig) is recalling certain model year 1997-2017 Low Floor transit buses. The front turn signals installed on standard profile (non-BRT) buses may not be sufficiently visible to other drivers or pedestrians. As such, these vehicles fail to comply with the requirements of Federal Motor Vehicle Safety Standard number 108, "Lamps, Reflective Devices, and Associated Equipment."
Consequence: The reduced visibility of the turn signals may increase the risk of a crash.
Remedy: Gillig will notify owners, and dealers will install turn signals that have increased visibility. The recall began June 7, 2019. Owners may contact Gillig customer service at 1-510-264-5073 or 1-800-735-1500.
View full details →Recall 18V511000 — EXTERIOR LIGHTING:TURN SIGNAL
| 178 vehicles affected
Defect: Gillig LLC (Gillig) is recalling certain 2012-2018 Gillig Low Floor vehicles. The front and rear turn signals on these vehicles may flash at different rates, potentially confusing other drivers of the vehicle's intention. As such, these vehicles fail to comply with the requirements of Federal Motor Vehicle Safety Standard (FMVSS) number 108, "Lamps, Reflective Devices, and Associated Equipment."
Consequence: The mismatched flashing may confuse other drivers, increasing the risk of a crash.
Remedy: Gillig will notify the owner of the buses, and dealers will reprogram the turn signals with new software, free of charge. The recall began August 30, 2018. Owners may contact Gillig customer service at 1-510-264-5073 or 1-800-735-1500.
View full details →Recall 18V418000 — EXTERIOR LIGHTING:TURN SIGNAL:FLASHER UNIT
| 25,579 vehicles affected
Defect: Gillig LLC (Gillig) is recalling certain 2001-2018 Gillig Low Floor transit buses. The turn signals may flash slowly, reducing their visibility to other drivers. As such, these vehicles fail to comply with the requirements of Federal Motor Vehicle Safety Standard (FMVSS) number 108, "Lamps, Reflective Devices, and Associated Equipment."
Consequence: The reduced visibility of the turn signals can increase the risk of a crash.
Remedy: Gillig will notify owners, and dealers will update the software that controls the turn flash rate, free of charge. The recall began on August 2, 2018. Owners may contact Gillig customer service at 1-510-264-5073 or 1-800-735-1500.
View full details →Recall 18V418000 — EXTERIOR LIGHTING:TURN SIGNAL
| 25,579 vehicles affected
Defect: Gillig LLC (Gillig) is recalling certain 2001-2018 Gillig Low Floor transit buses. The turn signals may flash slowly, reducing their visibility to other drivers. As such, these vehicles fail to comply with the requirements of Federal Motor Vehicle Safety Standard (FMVSS) number 108, "Lamps, Reflective Devices, and Associated Equipment."
Consequence: The reduced visibility of the turn signals can increase the risk of a crash.
Remedy: Gillig will notify owners, and dealers will update the software that controls the turn flash rate, free of charge. The recall began on August 2, 2018. Owners may contact Gillig customer service at 1-510-264-5073 or 1-800-735-1500.
View full details →Recall 16V451000 — EXTERIOR LIGHTING:BRAKE LIGHTS
| 112 vehicles affected
Defect: Gillig LLC (Gillig) is recalling certain model year 2012-2016 Lowfloor diesel-electric hybrid vehicles manufactured March 6, 2012, to June 7, 2016. The affected vehicles are equipped with stop lamp activation that may inadvertently flash the rear brake lights. As such, these vehicles do not comply with the requirements of Federal Motor Vehicle Safety Standard (FMVSS) No. 108, "Lamps, Reflective Devices,...
Consequence: Flashing brake lights may cause confusion to other drivers, increasing the risk of a crash.
Remedy: Gillig will notify owners, and dealers will install a new software update, free of charge. The recall began on July 2016. Owners may contact Gillig customer service at 1-800-735-1500.
View full details →Recall 16V011000 — SEATS
| 6,734 vehicles affected
Defect: Gillig LLC (Gillig) is recalling certain model year 2010-2015 Low Floor transit buses manufactured April 1, 2010 to October 30, 2015, equipped with Recaro Ergo-M Commercial Bus Driver Seats. The affected seats have J-Brackets that may be missing welds which could allow the seat belt anchorage assembly to separate from the J-Bracket.
Consequence: If the seatbelt anchorage assembly separates from the J-Bracket, the bus driver may not be properly restrained in the event of a crash increasing their risk of injury.
Remedy: Gillig will notify the owners, and dealers will inspect the seats to determine if welds are missing. Any J-Bracket that is missing welds will be removed and replaced, free of charge. The recall began on March 1, 2016. Owners may...
View full details →Recall 15V420000 — ELECTRICAL SYSTEM:WIRING:FRONT UNDERHOOD
| 6,971 vehicles affected
Defect: Gillig LLC (Gillig) is recalling certain model year 2010-2015 Low Floor transit buses manufactured April 13, 2010, to June 12, 2015. Due to the routing of the grid heater electrical power cable, the cable may chafe against a fuel injector hard line.
Consequence: If the electrical power cable rubs against the injector fuel line, the cable may short circuit or the fuel line may leak fuel. Either possibility increases the risk of a fire.
Remedy: Gillig will notify owners, and dealers will inspect the grid heater power cable/hard injector fuel line for wear, and will properly route and support the grid heater power cable, free of charge. The recall began on July 17, 2015. Owners...
View full details →Recall 15V262000 — ENGINE AND ENGINE COOLING:ENGINE
| 1,101 vehicles affected
Defect: Gillig LLC (Gillig) is recalling certain model year 2010-2015 Lowfloor vehicles manufactured August 26, 2010, to April 30, 2015. Excessive engine crankcase pressures may cause the 90-degree elbow of the vent tube assembly to detach from the crankcase ventilation breather, possibly allowing engine oil to come into contact with hot surfaces.
Consequence: If engine oil comes into contact with a hot surface, there is an increased risk of a fire.
Remedy: Gillig will notify owners, and dealers will secure the ends of the 90-degree elbow. In addition, the electronic control module (ECM) will be reprogrammed with software that can adjust the engine output under misfire conditions to limit crankcase pressures. These...
View full details →Recall 14V358000 — ENGINE AND ENGINE COOLING:ENGINE
| 648 vehicles affected
Defect: Gillig, LLC (Gillig) is recalling certain model year 2007-2014 Lowfloor transit buses manufactured September 26, 2007, through January 24, 2014. In the affected vehicles, the engine oil sampling hose may leak oil due to being routed too closely to hot engine exhaust components.
Consequence: If the sampling hose leaks oil in the presence of hot engine engine exhaust components, there is an increased risk of fire.
Remedy: Gillig will notify owners, and dealers will inspect the oil sampling hose. If the hose is routed too closely, the hose will be removed, replaced and rerouted to provide appropriate clearance of the hot components. The recall is expected to...
View full details →Recall 14V222000 — ELECTRICAL SYSTEM:WIRING
| 2,274 vehicles affected
Defect: Gillig LLC (Gillig) is recalling certain model year 2012-2014 Lowfloor transit buses manufactured October 15, 2012, through March 26, 2014, and equipped with electrical harnesses with overmolded J1939 connectors and non-insulated drain wires. The harnesses do not have heat shrink tubing on the drain wire and the overmold may not have sufficient resistance to water or corrosive chemical entry to...
Consequence: If the terminals corrode, there may be an intermittent electrical connection and possibly cause disruption or loss of the J1939 communication, resulting in interruptions of the engine, transmission, ABS and body controllers, increasing the risk of a crash.
Remedy: Gillig will notify owners, and dealers will replace the overmold connector, and install heat shrink tubing on the connector/cable junction, free of charge. The recall began in June 2014. Owners may contact Gillig customer service at 1-800-735-1500.
View full details →Recall 14V084000 — ENGINE AND ENGINE COOLING:ENGINE
| 643 vehicles affected
Defect: Gillig LLC is recalling certain model year 2010-2014 Lowfloor transit buses manufactured August 26, 2010, through February 14, 2014, and equipped with certain Cummins Westport model ISL G engines. Condensation in the intake manifold may freeze during cold weather conditions and interfere with the proper operation of the intake manifold pressure sensor.
Consequence: The improper operation of the sensor could induce elevated exhaust temperatures or flames from the exhaust pipe, increasing the risk of a vehicle fire.
Remedy: Cummins Inc. and Cummins Wesport Inc. will notify owners, and dealers will upload a new ECM calibration, free of charge. The recall began on March 20, 2014. Owners may contact Gillig LLC at 1-510-785-1500 or Cummins Inc. at 1-800-343-7357.
View full details →Owner Complaints for the 2012 GILLIG LOW FLOOR
No complaints have been filed with NHTSA for the 2012 GILLIG LOW FLOOR.
Safety Rating for the 2012 GILLIG LOW FLOOR
NHTSA has not yet tested the 2012 GILLIG LOW FLOOR in its New Car Assessment Program.
Technical Service Bulletins for the 2012 GILLIG LOW FLOOR
Gillig LLC has issued 4 technical service bulletins (TSBs) for the 2012 GILLIG LOW FLOOR. TSBs are notices sent by manufacturers to their dealers describing a known issue and the recommended repair procedure.
FS-2016-04 — FUEL SYSTEM, OTHER:DELIVERY:FUEL PUMP
THIS FIELD SERVICE BULLETIN MODIFIES AND CLARIFIES THE COOLANT FILL PROCEDURE ON ALL BAE HYBRID BUSES.
FS-2014-03 — SERVICE BRAKES, AIR:DRUM:SHOES/LININGS
THIS FIELD SERVICE BULLETIN APPLIES TO ALL CNG OR BAE HYBRID LOW FLOOR BUSES WITH DRUM BRAKES. IT ADVISES REPLACEMENT OF THE BOTTOM CENTER BOLT ON THE FRONT SUSPENSION AIR BAGS. DETAILS ARE PROVIDED REGARDING THE UPCOMING DELIVERY OF A REPLACEMENT PART FOR EACH BUS AT NO CHARGE, AS WELL...
FS-2013-02 — AIR BAGS
THIS FIELD SERVICE BULLETIN APPLIES TO ALL LOW FLOOR BUSES. IT PROVIDES INSTRUCTIONS FOR ADJUSTING THE FRONT AIR BAGS AFTER AN ALIGNMENT OR FOR RIDE ADJUSTMENT NEEDS.
FS-2012-06 — ENGINE AND ENGINE COOLING:EXHAUST SYSTEM:EMISSION CONTROL
THIS FIELD SERVICE BULLETIN APPLIES TO ALL LOW FLOOR BUSES WITH 2010 EMISSIONS COMPLIANT ENGINES. IT INFORMS OF OWNERS OF A TECHNICAL SERVICE BULLETIN FROM THE SUPPLIER OF THE DIESEL EXHAUST FLUID (DEF) TANK USED ON GILLIG BUSES. APPROXIMATELY 130 DEF TANKS WERE ASSEMBLED USING ZINC-PLATED STEEL DRAIN PLUGS IN...
NHTSA Investigations for the 2012 GILLIG LOW FLOOR
There are no NHTSA defect investigations on record for this vehicle.
Other Model Years of the GILLIG LOW FLOOR
- 2007 GILLIG LOW FLOOR — 0 complaints
- 2008 GILLIG LOW FLOOR — 1 complaint
- 2009 GILLIG LOW FLOOR — 0 complaints
- 2010 GILLIG LOW FLOOR — 0 complaints
- 2011 GILLIG LOW FLOOR — 0 complaints
- 2012 GILLIG LOW FLOOR (current)
- 2013 GILLIG LOW FLOOR — 0 complaints
- 2014 GILLIG LOW FLOOR — 2 complaints
- 2015 GILLIG LOW FLOOR — 0 complaints
- 2016 GILLIG LOW FLOOR — 1 complaint
- 2017 GILLIG LOW FLOOR — 0 complaints
Other GILLIG Models
- GILLIG 29 FOOT LOW FLOOR — 1 total complaint
- GILLIG PHANTOM — 1 total complaint
- GILLIG SCHOOL BUS — 1 total complaint
- GILLIG 35 AND 40 FOOT LOW FLOOR — 0 total complaints
- GILLIG 56815 — 0 total complaints
- GILLIG 85515 — 0 total complaints
- GILLIG BRT — 0 total complaints
- GILLIG BUS — 0 total complaints