1990 FORD F150 — Problems, Recalls & Safety Data
N/A
Safety Rating
290
Owner Complaints
5
Recalls
2
Service Bulletins
0
Investigations
Overview of the 1990 FORD F150
The 1990 FORD F150 has received a total of 290 safety complaints filed with the National Highway Traffic Safety Administration (NHTSA). There have been 5 recall campaigns affecting this vehicle, covering issues with FUEL SYSTEM, GASOLINE, ELECTRICAL SYSTEM:IGNITION, FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY. 2 technical service bulletins have been issued by Ford Motor Company for this model year. The most commonly reported problems involve the Fuel System Gasolinestorageauxillary Tankselector Devices (48 complaints), Fuel System Gasolinestoragetank Assembly (34 complaints), and Fuel System Gasolinestorageauxillary Tank (17 complaints).
Recalls for the 1990 FORD F150
NHTSA has recorded 5 recalls for the 1990 FORD F150, potentially affecting up to 10,699,321 vehicles.
Recall 01I008000 — FUEL SYSTEM, GASOLINE
| 1,556,221 vehicles affected
Defect: THIS IS NOT A SAFETY RECALL IN ACCORDANCE WITH THE SAFETY ACT. HOWEVER, IT IS DEEMED A SAFETY IMPROVEMENT CAMPAIGN BY THE AGENCY. VEHICLE DESCRIPTION: 1990-1993 FORD F-SERIES VEHICLES EQUIPPED WITH DUAL FUEL TANKS AND 4.9, 5.0,5.8, OR 7.5 LITER GASOLINE FUELED ENGINES. SOME VEHICLES CAN EXPERIENCE A CROSS TANK FUEL FLOW CONDITION DUE TO A DAMAGED CHECK VALVE IN...
Consequence: SHOULD THIS OCCUR, THE CAPACITY OF THE RECEIVING TANK MAY BE EXCEEDED AND FUEL MAY OVERFLOW FROM THE FILLER CAP.
Remedy: FORD IS EXTENDING THE WARRANTY FOR POTENTIAL FUEL CROSS-FLOW TO 12 YEARS OF SERVICE OR 150,000 MILES FROM THE VEHICLE'S WARRANTY START DATE, WHICHEVER OCCURS FIRST. THIS COVER WILL AUTOMATICALLY TRANSFER TO SUBSEQUENT OWNERS AT NO CHARGE. IF A VEHICLE...
View full details →Recall 96V071000 — ELECTRICAL SYSTEM:IGNITION
| 7,900,000 vehicles affected
Defect: THE IGNITION SWITCH COULD EXPERIENCE AN INTERNAL SHORT CIRCUIT.
Consequence: THIS CONDITION COULD CAUSE OVERHEATING, SMOKE, AND POSSIBLY FIRE IN THE STEERING COLUMN AREA OF THE VEHICLE.
Remedy: DEALERS WILL REPLACE THE IGNITION SWITCH.
View full details →Recall 93V125000 — FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY
| 1,131,000 vehicles affected
Defect: A MALFUNCTIONING CHECK VALVE WITHIN THE FUEL PUMP ASSEMBLY CAUSES A PORTION OF THE UNUSED FUEL FROM ONE TANK TO BE RETURNED TO THE SECOND TANK. WHEN THIS OCCURS, THE CAPACITY OF THE SECOND TANK CAN BE EXCEEDED, CAUSING FUEL SPILLAGE.
Consequence: SPILLED FUEL CAN RESULT IN A FIRE WHEN EXPOSED TO ASOURCE OF IGNITION.
Remedy: REPLACEMENT OF THE FUEL PRESSURE REGULATOR AND INSTALLATION OF REDUNDANT CHECK VALVES.
View full details →Recall 90V101000 — POWER TRAIN:AUTOMATIC TRANSMISSION:GEAR POSITION INDICATION (PRNDL)
| 111,000 vehicles affected
Defect: UNDER CERTAIN CONDITIONS, THE SNAP RING THAT LOCATES THE PARK GEAR ON THE OUTPUT SHAFT OF THE TRANSMISSION MAY FRACTURE.
Consequence: WHEN THE GEAR IS PLACED IN PARK, THE PARK GEAR WOULD NOTENGAGE, ALLOWING THE TRUCK TO ROLL FREELY IF THE PARKING BRAKE IS NOT PROPERLYSET. THIS COULD RESULT IN AN ACCIDENT.
Remedy: INSTALL IMPROVED SNAP RING AND REVISED TRANSMISSION EXTENSION HOUSING.
View full details →Recall 89V141000 — FUEL SYSTEM, GASOLINE:STORAGE:AUXILLARY TANK:SELECTOR DEVICES
| 1,100 vehicles affected
Defect: INCORRECTLY INSTALLED FUEL LINE CONNECTORS HAVE FUEL SUPPLY AND RETURN LINES CROSSED.
Consequence: FUEL COULD BE TRANSFERRED FROM ONE TANK TO THE OTHER,POSSIBLY RESULTING IN FUEL OVERFLOW AND SPILLAGE, IN PRESENCE OF AN IGNITIONSOURCE, A FIRE COULD OCCUR.
Remedy: REPLACE FUEL LINE ASSEMBLY.
View full details →Owner Complaints for the 1990 FORD F150
290 complaints have been filed with NHTSA for the 1990 FORD F150. Below is a breakdown by vehicle component.
Most Recent Complaints
TL* THE CONTACT OWNS A 1990 FORD F-150. THE CONTACT STATED THAT GASOLINE FUEL WAS ABNORMALLY LEAKING FROM THE FUEL TANK AND THE REAR FUEL TANK WAS PUMPING FUEL INTO THE FRONT FUEL TANK. THE CONTACT LOCATED A RECALL UNDER NHTSA CAMPAIGN ID NUMBER: 93V125000 (FUEL SYSTEM: TANK ASSEMBLY), BUT WAS INFORMED BY THE MANUFACTURER THAT THE RECALL WAS EXPIRED. THE VEHICLE WAS NOT REPAIRED. THE FAILURE AND CURRENT MILEAGE WAS 180,000.
TL*THE CONTACT OWNS A 1990 FORD F150. THE CONTACT STATED THAT THERE WERE TWO FUEL TANKS IN HER VEHICLE. WHEN SHE ADDED FUEL TO THE INTENDED TANK, IT WOULD FORCE FUEL INTO THE AUXILIARY TANK AND LEAK OUT OF THE TANK. THE FAILURE OCCURRED EVERY TIME FUEL WAS ADDED TO THE VEHICLE. THE DEALER STATED THAT RECALL #93V125000 EXPIRED; HOWEVER, THEY WOULD REPAIR THE VEHICLE AT NO COST. THE MANUFACTURER WAS NOT NOTIFIED. THE VEHICLE HAS NOT BEEN REPAIRED. THE CURRENT MILEAGE WAS 86,236. THE FAILURE MILEAGE WAS APPROXIMATELY 86,000.
TL*THE CONTACT OWNS A 1990 FORD F150. AFTER FILLING BOTH OF THE GAS TANKS IN THE VEHICLE, THE CONTACT NOTICED THE FUEL LEVEL DECREASING. THE FAILURE WAS NOTICED WHILE DRIVING 30 MPH. AFTER DRIVING FOR TEN MILES, HE PULLED THE VEHICLE OVER AND NOTICED FUEL LEAKING FROM THE REAR GAS TANK. THE CONTACT SWITCHED THE FUEL USAGE TO THE FRONT FUEL TANK. THE VEHICLE WAS TAKEN TO A LOCAL REPAIR SHOP, BUT THE TECHNICIAN COULD NOT DETERMINE THE CAUSE OF THE FAILURE. THE TECHNICIAN ADVISED THE CONTACT TO TAKE THE VEHICLE TO THE DEALER FOR FURTHER INSPECTION. HE DISCOVERED NHTSA CAMPAIGN ID NUMBERS 01I008000 (FUEL SYSTEM, GASOLINE) AND 93V125000 (FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY). THE DEALER STATED THAT THE BA AND AA CONNECTORS, GASKET, TWO RETAINERS, TWO FUEL FILTERS, VALVES, AND THE O RING ON THE TANK HAD ALL FAILED. THE VEHICLE WAS REPAIRED AT THE COST OF $765.47. THE CONTACT IS IN THE PROCESS OF NOTIFYING THE MANUFACTURER. THE FAILURE MILEAGE WAS 118,000 AND CURRENT MILEAGE WAS 123,487. UPDATED 5/27/09 *CN THE CONSUMER STATED GAS STARTED TRANSFERRING FROM ONE TANK TO ANOTHER. UPDATED 06/02/09.*JB
TL*THE CONTACT OWNS A 1990 FORD F150. AFTER FILLING BOTH OF THE GAS TANKS IN THE VEHICLE, THE CONTACT NOTICED THE FUEL LEVEL DECREASING. THE FAILURE WAS NOTICED WHILE DRIVING 30 MPH. AFTER DRIVING FOR TEN MILES, HE PULLED THE VEHICLE OVER AND NOTICED FUEL LEAKING FROM THE REAR GAS TANK. THE CONTACT SWITCHED THE FUEL USAGE TO THE FRONT FUEL TANK. THE VEHICLE WAS TAKEN TO A LOCAL REPAIR SHOP, BUT THE TECHNICIAN COULD NOT DETERMINE THE CAUSE OF THE FAILURE. THE TECHNICIAN ADVISED THE CONTACT TO TAKE THE VEHICLE TO THE DEALER FOR FURTHER INSPECTION. HE DISCOVERED NHTSA CAMPAIGN ID NUMBERS 01I008000 (FUEL SYSTEM, GASOLINE) AND 93V125000 (FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY). THE DEALER STATED THAT THE BA AND AA CONNECTORS, GASKET, TWO RETAINERS, TWO FUEL FILTERS, VALVES, AND THE O RING ON THE TANK HAD ALL FAILED. THE VEHICLE WAS REPAIRED AT THE COST OF $765.47. THE CONTACT IS IN THE PROCESS OF NOTIFYING THE MANUFACTURER. THE FAILURE MILEAGE WAS 118,000 AND CURRENT MILEAGE WAS 123,487. UPDATED 5/27/09 *CN THE CONSUMER STATED GAS STARTED TRANSFERRING FROM ONE TANK TO ANOTHER. UPDATED 06/02/09.*JB
TL*THE CONTACT OWNS A 1990 FORD F150. WHILE THE ENGINE WAS OPERATING, FUEL WAS LEAKING OUT OF THE FILLER NECK OF THE FRONT FUEL TANK IN LARGE AMOUNTS. THE VEHICLE WAS TAKEN TO AN INDEPENDENT MECHANIC AND THEY REFERENCED NHTSA CAMPAIGN ID NUMBER 93V125000 (FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY). THE RECALL STATES THAT A MALFUNCTIONING CHECK VALVE WITHIN THE FUEL PUMP ASSEMBLY CAUSES A PORTION OF THE UNUSED FUEL FROM ONE TANK TO BE RETURNED TO THE SECOND TANK. WHEN THIS OCCURS, THE CAPACITY OF THE SECOND TANK CAN BE EXCEEDED, CAUSING FUEL SPILLAGE. THE CURRENT AND FAILURE MILEAGES WERE LESS THAN 160,000. UPDATED 11/07/08 *BF UPDATED 11/13/08.*JB
View all Fuel System Gasolinestorageauxillary Tankselector Devices complaints →
Safety Rating for the 1990 FORD F150
NHTSA has not yet tested the 1990 FORD F150 in its New Car Assessment Program.
Technical Service Bulletins for the 1990 FORD F150
Ford Motor Company has issued 2 technical service bulletins (TSBs) for the 1990 FORD F150. TSBs are notices sent by manufacturers to their dealers describing a known issue and the recommended repair procedure.
951112 — POWER TRAIN:AUTOMATIC TRANSMISSION
REVISED DESIGN TRANSMISSION REAR CASE BUSHING. *TW
9597 — SUSPENSION:FRONT
UNKNOWN
NHTSA Investigations for the 1990 FORD F150
There are no NHTSA defect investigations on record for this vehicle.
Other Model Years of the FORD F150
- 1985 FORD F150 — 45 complaints
- 1986 FORD F150 — 78 complaints
- 1987 FORD F150 — 107 complaints
- 1988 FORD F150 — 170 complaints
- 1989 FORD F150 — 241 complaints
- 1990 FORD F150 (current)
Other FORD Models
- FORD F-150 — 45,660 total complaints
- FORD EXPLORER — 42,140 total complaints
- FORD ESCAPE — 34,654 total complaints
- FORD FOCUS — 29,539 total complaints
- FORD FUSION — 28,243 total complaints
- FORD TAURUS — 23,867 total complaints
- FORD WINDSTAR — 19,456 total complaints
- FORD EDGE — 17,247 total complaints