Technical Service Bulletin ITB14023 — 2009 INFINITI G37
STRUCTURE:BODY:ROOF AND PILLARS
Bulletin Details
| TSB ID | ITB14023 |
| Manufacturer | |
| Vehicle | 2009 INFINITI G37 |
| Component | STRUCTURE:BODY:ROOF AND PILLARS |
| Communication Date |
Bulletin Summary
SERVICE INFORMATION If the hydraulic unit assembly (pump assembly) needs to be tested for any reason, the convertible top should not sink or drop further than 250 mm (9.84 inches) within one (1) minute or less when opened as shown in Figure 1. - If the convertible top sinks further than 250 mm (9.84 inches) within one (1) minute or less - the pump assembly needs to be replaced. - If the convertible top does not sink further than 250 mm (9.84 inches) within one (1) minute or less - the pump assembly is OK. NOTE: This instruction supersedes the previous 15 mm measurement threshold specified in SIR video # 165. CAUTION: The convertible top should only be partially opened for service and should not be left in this position as damage may result. See this bulletin for further detail.
About Technical Service Bulletins
A Technical Service Bulletin (TSB) is a document issued by a vehicle manufacturer to its dealers, describing a known issue with a specific vehicle or set of vehicles and the recommended procedure to fix it. Unlike recalls, TSBs are not mandatory and are typically only performed if an owner reports the related issue. However, TSBs can be an indicator of common problems with a vehicle.