NHTSA Complaint #10460890 — 2011 IC CE300

SERVICE BRAKES issue reported to NHTSA

Check any vehicle history by VIN - Free vehicle history report

Complaint Details

ODI Number 10460890
Vehicle 2011 IC CE300
Component SERVICE BRAKES
Date of Incident
Date Filed
Mileage 24,000 miles
Crash No
Fire No
Injuries 0
Deaths 0
Vehicle Towed No
State NY

Consumer Description

I REPLACED THE OEM FRONT KSMA2124702QP MERITOR BRAKES WITH THE NEW KSMA20014702QP REDUCED STOPPING DISTANCE MERITOR FRONT BRAKES AND AFTER ONLY 1519 MILES SAW THE LINING MATERIAL MOVING (BACK AND FORTH MOVEMENT)ON THE STEEL TABLE WHEN APPLYING AND RELEASING THE FOOT BRAKE WITH 95PSI IN SYSTEM WHILE LOOKING THROUGH THE BACKING PLATE! APPEARING TO BE LOOSE RIVETS HOLDING MATERIAL TO STEEL TABLE! HAD MERITOR REPRESENTATIVE HERE ON 5-22-12 TO WITNESS AND CONFIRM MOVEMENT AND WAS DIRECTED TO REMOVE SHOES AND INSTALL NEW ONES.DID SO ON 6-6-12 AND PUT OEM KSMA2124702QP MERITOR FRONT BRAKES BACK ON AND ALL OK AT THIS TIME! *JS
Check any vehicle history by VIN - Free vehicle history report