NHTSA Complaint #10260706 — 2006 BUELL XB12S
ELECTRICAL SYSTEM issue reported to NHTSA
Complaint Details
| ODI Number | 10260706 |
| Vehicle | 2006 BUELL XB12S |
| Component | ELECTRICAL SYSTEM |
| Date of Incident | |
| Date Filed | |
| Mileage | 6,250 miles |
| Crash | No |
| Fire | No |
| Injuries | 0 |
| Deaths | 0 |
| Vehicle Towed | No |
| State | FL |
Consumer Description
MOTORCYCLE STARTED STALLING WHILE DRIVING AND AT LIGHTS. THROTTLE WAS UNRESPONSIVE AND ALMOST CAUSED AN ACCIDENT. BIKE WOULD BACKFIRE AND NOT IDLE. AT 6250 MILES SIX WIRES FROM THE ECM HARNESS RUBBED THE SHARP METAL SHOCK FLUID LINE AND SHORTED OUT THE COIL, TPS, O2 SENSOR AND INJECTORS. THE BIKE WAS UNDRIVEABLE. DEALER RESOLDERED HARNESS. THIS IS THE SECOND RUB THROUGH HARNESS PROBLEM. ENGINE HARNESS WAS COVERED WITH ELECTRICAL CONDUIT AND SHARP FLUID LINE WAS COVERED WITH RUBBER FUEL LINE. *TR
Related Complaints for the 2006 BUELL XB12S
Other ELECTRICAL SYSTEM Complaints
#10251273
REMOVED SEAT AND NOTICED HARNESS TO ECM CHAFFING ON SEAT. PROBLEM COULD CAUSE ENGINE NOT TO RUN. WIRE HARNESS FELT WA...
Recent Complaints for the 2006 BUELL XB12S
#10201606
STRUCTURE:MOTORCYCLE:KICKSTAND/CENTER STAND