NHTSA Complaint #10260706 — 2006 BUELL XB12S

ELECTRICAL SYSTEM issue reported to NHTSA

Check any vehicle history by VIN - Free vehicle history report

Complaint Details

ODI Number 10260706
Vehicle 2006 BUELL XB12S
Component ELECTRICAL SYSTEM
Date of Incident
Date Filed
Mileage 6,250 miles
Crash No
Fire No
Injuries 0
Deaths 0
Vehicle Towed No
State FL

Consumer Description

MOTORCYCLE STARTED STALLING WHILE DRIVING AND AT LIGHTS. THROTTLE WAS UNRESPONSIVE AND ALMOST CAUSED AN ACCIDENT. BIKE WOULD BACKFIRE AND NOT IDLE. AT 6250 MILES SIX WIRES FROM THE ECM HARNESS RUBBED THE SHARP METAL SHOCK FLUID LINE AND SHORTED OUT THE COIL, TPS, O2 SENSOR AND INJECTORS. THE BIKE WAS UNDRIVEABLE. DEALER RESOLDERED HARNESS. THIS IS THE SECOND RUB THROUGH HARNESS PROBLEM. ENGINE HARNESS WAS COVERED WITH ELECTRICAL CONDUIT AND SHARP FLUID LINE WAS COVERED WITH RUBBER FUEL LINE. *TR

Related Complaints for the 2006 BUELL XB12S

Other ELECTRICAL SYSTEM Complaints

#10251273 REMOVED SEAT AND NOTICED HARNESS TO ECM CHAFFING ON SEAT. PROBLEM COULD CAUSE ENGINE NOT TO RUN. WIRE HARNESS FELT WA...

Recent Complaints for the 2006 BUELL XB12S

#10201606 STRUCTURE:MOTORCYCLE:KICKSTAND/CENTER STAND TL*THE CONTACT OWNS A 2006 BUELL XB12S. WHILE DRIVING VARIOUS SPEEDS UP TO 130 MPH, THE KICKSTAND ALMOST DETACHED FR...
Check any vehicle history by VIN - Free vehicle history report