NHTSA Complaint #10244614 — 1999 HARNEY RENEGADE
SERVICE BRAKES, HYDRAULIC issue reported to NHTSA
Complaint Details
| ODI Number | 10244614 |
| Vehicle | 1999 HARNEY RENEGADE |
| Component | SERVICE BRAKES, HYDRAULIC |
| Date of Incident | |
| Date Filed | |
| Mileage | 79,049 miles |
| Crash | No |
| Fire | No |
| Injuries | 0 |
| Deaths | 0 |
| Vehicle Towed | No |
| State | CA |
Consumer Description
REAR AXLE SEAL WAS LEAKING. WHEN REPAIRING THE SEAL, THE MECHANIC SAW THE BRAKE CALIPER WAS HITTING THE SUSPENSION BOLT. WHEN THE BRAKES WERE APPLIED THE CALIPER PUSHED THE ROTOR AND HUB OUT WHICH CAUSED THE SEAL TO LEAK. THE AXLE COULD FAIL. A MONACO CORP. MECHANIC SAID TO RELOCATE THE CALIPER TO THE REAR OF THE ROTOR. THIS SOLVED THE PROBLEM. *TR